Detection of Antibodies Directed Towards Dengue Virus by PRNT

<<Return to Search Results

Requisition Forms

Reference Details

Description:

Serological detection of neutralizing antibodies directed towards dengue (DEN) virus by Plaque Reduction Neutralization Test (PRNT).

Test Category:
Serology
Pathogen:
Dengue virus
Illnesses and Diseases:
  • Dengue hemorrhagic fever (DHF)
  • Dengue fever
  • Dengue shock syndrome
Specimen:

Serum. Minimum volume of 250 µl required.

Collection Method:

2 mL screw cap tubes.

Specimen Processing, Storage and Shipping:

Store samples refrigerated or frozen until shipped for testing. Ship frozen samples on dry ice, and refrigerated samples on wet ice

Transportation of Dangerous Goods:

Shipping of specimens shall be done by a TDG certified individual in accordance with TDG regulations. For additional information regarding classification of specimens for the purposes of shipping, consult either Part 2 Appendix 3 of the TDG Regulations or section 3.6.2 of the IATA Dangerous Goods Regulations as applicable.

 

Patient Criteria:

Suspected dengue virus infection and relevant travel history. Submitted samples will first be analysed by the Viral Zoonoses Diagnostic Laboratory by Dengue IgM/IgG ELISA to determine if the patient has developed anti-flavivirus antibodies. Samples that are reactive can be further analysed for the presence of neutralizing antibodies. Samples that are ELISA non reactive (negative) will not be tested by PRNT.

Accompanying Documentation:

Completed Viral Zoonoses requisition including sender laboratory name, address and telephone number. Patient name and / or identifier (specimen reference number), date of birth, test(s) requested, collection date of specimen, date of on-set of symptoms, and clinical and travel history of patient.

Comments:

Dengue PRNT is often performed alongside other flavivirus PRNT to differentiate virus causing illness due to the high level of seroprevalence of Dengue virus.

This test is considered investigational as it has not been extensively validated or verified.

Methods and Interpretation of Results:

Testing is performed, in whole or in part, using a lab-developed test which has not been fully validated/verified due to a lack of well-characterized panel.

The detection of IgG antibodies in a single serum sample is indicative of past or present exposure to this virus. A 4 fold rise or greater in neutralizing antibody titre, or seroconversion in paired sera, is required to document a "confirmed case" of infection.

IgM can persist in serum for up to a year or more after arbovirus exposure.  Thus, detection of IgM by itself is not sufficient for confirmation of acute infection, but is consistent with an exposure at an undetermined time.

Isolation of an arbovirus or detection of nucleic acid by real-time RT-PCR in a clinical specimen provides clear evidence of infection associated with the current clinical illness.

 

Turnaround Time:

21 calendar days after the completion of preliminary ELISA testing.

Contact:
Phone #: (204) 789-7037
Fax: (204) 789-2018
References:
  1. WHO. 2007. Guidelines for plaque reduction neutralization testing of human antibodies to dengue viruses.
Related Information: